How to Determine Whether the DCY Series Gearbox System Requires Maintenance Based on Test Results
Determination of natural frequency test results1. The deviation between the measured natural frequency and the factory benchmark value exceeds 15%, indicating a significant decrease in system stiffness and requiring targeted maintenance and troubleshooting.

2. The natural frequency during operation has decreased by more than 10% compared to the historical baseline value, indicating a high probability of gear wear, excessive bearing clearance, or loose foundation. Immediate shutdown inspection is required.
3. The difference between the excitation frequency corresponding to the working speed of the reducer and the measured natural frequency is less than 10%, indicating that it has entered the resonance risk zone. It is necessary to immediately adjust the operating parameters or implement structural reinforcement and maintenance.
2、 Quantitative threshold determination of vibration velocity
According to the GB/T 6075.3 standard, the DCY series hard tooth reducer uses the effective value of vibration velocity as the core judgment index:
1. ≤ 4.5mm/s: In good operating condition, no additional maintenance is required, and regular inspections can be maintained.
2. 4.5~7.1mm/s: Upon entering the warning zone, it is necessary to increase the frequency of testing, arrange planned maintenance, and not immediately stop the machine.
3. >7.1mm/s: reaching the danger threshold, there is a serious risk of malfunction, and the machine must be immediately shut down for comprehensive maintenance.
4. Under heavy load conditions in mines, the limit can be relaxed to ≤ 6.0mm/s, and if it exceeds this value, it still needs to be disposed of according to the danger level.
3、 Accurate fault diagnosis based on spectral characteristics
Through FFT spectrum analysis, the fault type can be directly located and corresponding maintenance actions can be triggered:
1. 1-fold rotation frequency amplitude dominant: indicates rotor imbalance and requires dynamic balance calibration and maintenance.
2. The peak value of the 2-fold rotation frequency significantly increases, and the axial vibration is prominent: the pointing coupling is not aligned, and a laser alignment instrument needs to be used to recalibrate the coaxiality.
3. The significant increase in meshing frequency and sideband indicates wear and pitting on the tooth surface. It is necessary to dismantle and inspect the gear wear, and replace the gear pair if it exceeds the standard.
4. Peak appearance of bearing characteristic frequency: indicates damage to the inner/outer ring and rolling elements of the bearing, and immediate replacement of the bearing is required.
5. 0.5X, 1.5X and other harmonics appear: it indicates that the anchor bolts are loose and the foundation stiffness is insufficient. The bolts need to be re tightened and the foundation needs to be reinforced.
4、 Auxiliary judgment of temperature and oil test results
1. During operation, if the equilibrium temperature of the casing exceeds 90 ℃ and the temperature of the bearings exceeds 95 ℃, the machine should be stopped immediately for maintenance after eliminating the abnormal oil level.
2. Oil testing reveals that the particle size of metal debris is greater than 0.1mm, or the proportion of large particles in the iron spectrum exceeds 10%, indicating severe wear of the gear/bearing and requiring disassembly and maintenance.
3. Lubricating oil oxidation deterioration and emulsification phenomenon, even if the vibration frequency index is normal, it is necessary to immediately replace the oil and investigate the sealing failure problem.