How to ensure the correct installation direction of the new fan when replacing the cooling fan of WPA250-30 worm gear reducer
1、 Pre installation benchmark confirmationThe cooling fan of WPA250-30 must be installed on a high-speed worm shaft, not a low-speed worm gear shaft, in order to rely on high speed to generate sufficient wind pressure to remove heat from the box.

Core air duct requirement: When the fan is running, the airflow must blow directly onto the surface of the heat sink of the cast iron box of the reducer, forcing convection to take away the heat conducted by the box, rather than discharging hot air to the outside.
2、 Step 1: Identify the priority direction for judgment
On the casing or blades of a regular industrial fan, arrows indicating the direction of airflow and the rotation of the impeller will be directly marked. The direction of the arrows is the direction of the air outlet, and it is necessary to ensure that the air outlet side is facing the heat dissipation surface of the gearbox body.
Some fans will be labeled with the words "FRONT" (inlet side, facing outward) and "BACK" (outlet side, facing the box), and can be directly aligned according to the markings.
3、 Step 2: Structural feature assisted localization
The side with a motor fixed cross support frame and no protective net is the fan outlet surface and must be installed facing the gearbox body.
The side with a complete protective grille and no internal support crossbeam is the air intake surface, facing towards the outer free space to ensure unobstructed air intake.
4、 Step 3: Power on and jog to verify the wind direction
Before fixing the fan, do not lock the bolts. Apply power for a short period of time and jog it. Use thin paper to approach both sides of the fan: the side where the paper is blown open is the air outlet surface, which should face the box directly; The side where the paper is adsorbed is the air inlet surface, which needs to face outward.
If the fan rotates in the opposite direction, the air volume is only 30%~60% of the normal value, which completely fails to meet the heat dissipation requirements of WPA250-30 heavy-duty working conditions. The oil temperature will quickly exceed the safety threshold of 85 ℃.
5、 Step 4: Verify and confirm the air duct of the entire machine
Manually rotate the worm shaft several times to confirm that the fan blades and fan cover are not scratched or stuck, the distance between the inlet side and surrounding equipment is ≥ 50mm, and there are no obstructions blocking the inlet air.
Conduct a 30 minute no-load trial run and monitor the surface temperature of the box. Under normal heat dissipation conditions, the temperature rise of the box should be ≤ 35 ℃. If the temperature rise exceeds 40 ℃, the machine should be stopped immediately to recheck the installation direction of the fan.