How to urgently handle abnormal temperature rise of ZLY710-18-2 hard tooth gear reducer
Emergency measures for abnormal temperature rise of ZLY710-18-2 hard tooth gear reducer, combined with its high power and heavy load working conditions, are recommended to be implemented according to the following priorities: 1、 Immediate shutdown inspection (safety priority) Forced shutdown conditions When the oil temperature continues to exceed 90 ℃ or the bearing temperature reaches 120