Precautions for Installing New Seals on WPX147-15-B Worm Gear Reducer
When fitting a new seal to the WPX147-15-B worm gear reducer, follow the precautions listed below: 1. Pre-installation preparations Verify equipment condition: Confirm the reducer is fully shut down, isolate the power supply, and fit warning tags. This prevents safety hazards triggered by accidental equipment startup during seal fitting work. Inspect seals: Thoroughly examine the new seals fo